The transformer comprehensive test bench mainly tests the no-load and load characteristics of the power transformer and the distribution transformer, and can also perform the double frequency induction and power frequency withstand voltage test on the tested transformer. The measurement part of the device is controlled by high-grade single-chip microcomputer. The digital display, no-load, short-circuit and other test data are synchronously sampled by the single-chip microcomputer, which avoids the errors caused by the voltage, ammeter and power meter readings in the traditional test method and calculated by manual calculation. Transformer comprehensive test bench can detect various items: three-phase voltage RMS, three-phase current RMS, three-phase active loss, three-phase reactive loss, three-phase average voltage, three-phase voltage average, three-phase current average Value, total power, percentage of no-load current, percentage of impedance voltage, frequency, power factor, frequency doubled induction test, variable ratio group test, etc. He has made outstanding contributions to the testing of transformers.
Test principle of three-phase transformer or three-phase voltage transformer of transformer integrated test bench: The 16-bit high-precision high-speed A/D converter inside the instrument measures the output of the high-voltage side and the input voltage of the low-voltage side, and calculates the ratio of the ratio through the high-performance single-chip microcomputer. After the user inputs the ratio according to the transformer nameplate, the instrument automatically calculates and displays the ratio error value.
Single-phase transformer or transformer measurement methods, calculation and processing are the same as three-phase measurements. When measuring three-phase transformers, the phase difference of the line voltage of the high and low voltage coils is different due to the different coil connection modes of the transformer. It can be in phase or reverse phase, or it can be different from one angle. The instrument also measures the high voltage while measuring the transformation ratio. The phase difference between the side and the low voltage side, and then determine the transformer connection group of 1~12 according to the phase difference. When measuring single-phase transformer or transformer, the instrument is based on the phase of the high-voltage side. When the display value is “+â€, the low-voltage side and the high-voltage side are displayed in phase. When the display value is “-â€, the low-voltage side and the high-voltage side are indicated. Inverted, if "!" is displayed, it means that it is not in phase or in phase.
[Related data download] Simple method for discriminating three-phase transformer connection group
36V Bms,Bms For E-Bike,Bms For Scooter,10S 36V 15A Bms
HuiZhou Superpower Technology Co.,Ltd. , https://www.spchargers.com